Skip to Content

SpectraChem SC-200EL

The SpectraChem SC-200EL is a fully automatic biochemistry analyzer built for specialized and routine biochemistry test parameters. It runs 200 photometric tests per hour — up to 450 with ISE — from a compact bench footprint, with 40 cooled reagent and 40 cooled sample positions, built-in maintenance-free biosensor electrolytes (Na, K, Cl, iCa, pH, tCa) and a barcode reader for both reagent and sample. Smaller footprint, greater diagnostic power.
SpectraChem SC-200EL
Functional Modules

Reaction Disc & Cuvette Washer

  • Automatic 7-step cleaning & drying.
  • Spring style washer needle for internal/external auto cleaning.
  • Simultaneous cuvette cleaning by cleaning solution & DI water.
  • 60 position long-life UV PMMA cuvettes (standard delivery).
  • Easy replacement of individual cuvette.
  • Permanent optical glass cuvette (optional).

Sample Probe & Reagent + Sample Mixer

  • Independent stirring arm.
  • Reagent + sample mixing may also be programmed if the stirrer does not work.
  • Reagent/sample probe with liquid level sensor, probe crash detection and a Teflon-coated tip.
  • Effective outside & inside cleaning mechanism.

Sample & Reagent Disc with Bottle Cap Ring

  • 40 cooled reagent positions, 18 mL and 5 mL reagent bottles.
  • Unique bottle cap ring with non-reactive cap to close reagent bottles after the run.
  • Removable reagent/sample tray — place it straight into the refrigerator after the run.
  • 40 cooled sample positions; samples may be placed randomly, including standard, QC and emergency/STAT.
  • Samples can sit in the primary collection tube or a sample cup.
  • Built-in barcode reader for reagent & sample.

Built-in Maintenance-Free Electrolytes

  • Biosensor technology — no electrode required; each reagent pack ships with its biosensor.
  • Parameters: Na, K, Cl, iCa, pH, tCa.
  • 250 tests/hour for electrolyte parameters.
Technical Parameters
  • Test speed: photometric 200 tests/hour; ISE 4 parameters 250; photometric with ISE 400–450 tests/hour.
  • Chemistry on board: 40 positions.
  • Analysis method: end point, fix-time (two points), kinetic, colorimetry, turbidimetry, two wavelength, double reagent, multi-standard, ISE 4 parameters.
  • Sample disk: 40 positions, random placement including standard, QC and emergency/STAT; original tube or serum cup.
  • Reagent disk: 40 positions, 20 mL or 5 mL bottles, refrigerated compartment.
  • Sample volume: 2–50 µL in 0.1 µL steps. Reagent volume: R1 110–300 µL, R2 10–250 µL in 1 µL steps.
  • Working reagent volume: 180–360 µL (200 µL recommended).
  • Light source: 6 V, 10 W halogen-tungsten lamp. Wavelength: 340–800 nm (340, 405, 450, 510, 546, 578, 620, 660, 700 nm), accuracy ±2 nm.
  • Optical system: static optical fiber transit system, optical filter style, multi-wavelength spectrophotometer.
  • Detecting cycle: 18 seconds. Max. reaction time: 14 minutes. Reaction temperature: 37 ± 0.1 °C warm air incubation.
  • Reaction cuvette: 6.5 mm × 7 mm × 22 mm, 5 mm optical path; 60 reusable UV plastic cuvettes, glass option available.
  • Absorbance range: 0.0000–4.0000 Abs, resolution 0.001 Abs, repeatability CV ≤ 2.5%, stability < 0.01 Abs per hour.
  • QC: multi-QC function, random QC insertion, stored/displayed/printed QC diagrams, 3 QC materials per test.
  • Automatic dilution: user programmable. Unique feature: user-selectable reflex testing and linearity check.
  • Data processing: stores and edits more than 300 test parameters. Operating system: Windows 10 or higher.
  • Power: 110 or 220 V, 50/60 Hz, three-core grounded cord; input power 350 VA; fuse T10A 250 V.
  • Communication: instrument RS-232; host computer RS-232 or Ethernet.
  • Working environment: 10–30 °C, ≤ 90% RH, 70.0–106.0 kPa, water consumption 5 L/hour.
  • Dimensions: 415 (W) × 565 (D) × 350 (H) mm. Weight: 29 kg net.
Special Chemistries & Test Profiles

SC-200EL special chemistries

ACE, ADA, AMM, ANTI-CCP, APO-A, APO-B, ASO, CRP, C-3, C-4, CHE, COPPER, CO-2, CYS-C, D-Dimer, D-3HB, ETHANOL, FERRITIN, Fructosamine, HBDH, Iron, UIBC, HCY, HAPTOGLOBIN, HFABP, Hs-CRP, LACTAT, Lipase, LPA, Lithium, MALB, NGAL, PYRUVATE, SIALIC Acid, Vit-D, FKLC, FLLC, CITRIC ACID, G6PD, ALDOLASE, 1,5AG, TBA.

Electrolytes

Na, K, Cl, iCa, tCa, pH.

Routine test profiles

Cardiac, Pancreatic, Inorganic Ion, Renal, Diabetes, Anemia, Immune, Hepatic, Inflammation, Reumatism, ISE, Lipids.

More parameters will be available soon.

Frequently asked questions

What throughput can I expect?
200 photometric tests per hour, 250 tests per hour on the 4-parameter ISE, and 400 to 450 tests per hour running photometric with ISE.

Which electrolytes does it measure?
Na, K, Cl, iCa, pH and tCa, using biosensor technology. Each reagent pack carries its own biosensor, so there is no electrode to replace or condition.

How many sample and reagent positions are there?
40 cooled positions on each disk. Samples can be placed at random — standard, QC and emergency/STAT — in the primary collection tube or a sample cup.

How much sample does a test use?
2 to 50 µl in 0.1 µl steps, with a working reagent volume of 180–360 µl (200 µl recommended).

Are the cuvettes disposable?
No — 60 long-life UV PMMA cuvettes are re-used and can be replaced individually. Permanent optical glass cuvettes are available as an option.

How are the cuvettes cleaned?
An automatic 7-step cleaning and drying cycle, washing with cleaning solution and DI water simultaneously.

What quality control does it support?
Multi-QC that can be inserted at random, with stored, displayed and printable QC diagrams and up to three QC materials per test.

How many test parameters can it hold?
More than 300 can be edited and stored on board.

Enquiry

Request a quote for the SpectraChem SC-200EL

Tell us your throughput and test menu and we will confirm configuration, reagents and pricing.

Get a quote

Tell us what your lab needs.

Share your throughput and test menu and we will confirm configuration, reagents and pricing.

Or call 011 41064962